Innovating and creating

World Class Burners

The Absolute Extreme Burner TM can deliver an Exhaust Velocity Harmonic TM (EVH) that can dramatically increase heat transfer efficiency in a fire-tube application. The ACI burner has 100% combustion efficiency, leaving zero carbon monoxide (CO) emissions in the exhaust stream. This is considered a platform technology and we believe it will set a new standard for NOx and CO emissions as well as how heat transfer efficiency is delivered and measured.

View Explainer Video

Product Lineup

Highlights

Burner Nozzle Size:

1″

BTU/hr Output:

300K

Combustion Chamber OD:

5.563″

Specifications

Total Length:

24″

Approximate Weight:

90 LB

Fuel Nozzle Pressure:

< 2 PSI

Performance

Forced Air Pressure:

< 15 PSI

Flame length:

< 8″

Liquid Cooled Flow Rate@ 60 PSI:

25 LPM

Approximate Output Temp.:

1010 C/1850 F

Approximate Fire Tube Exhaust:

175-200 C/350-400 F

Efficiency

Combustion Efficiency:

100%

Apparatus Efficiency (including electricity):

80-85% HHV

Fuel:

Natural Gas/ Propane

Emissions (Corrected for 3% O2):

O2-6%,

CO-0ppm, Nox-15ppm

Certifications, CSA/ Ansi:

Pending

Highlights

Burner Nozzle Size:

2″

BTU/hr Output:

1.5MM

Combustion Chamber OD:

8.625″

Specifications

Total Length:

35″

Approximate Weight:

145 LB

Fuel Nozzle Pressure:

< 3 PSI

Performance

Forced Air Pressure:

< 15 PSI

Flame length:

< 8″

Liquid Cooled Flow Rate@ 60 PSI:

25 LPM

Approximate Output Temp.:

1010 C/1850 F

Approximate Fire Tube Exhaust:

175-200 C/350-400 F

Efficiency

Combustion Efficiency:

100%

Apparatus Efficiency (including electricity):

80-85% HHV

Fuel:

Natural Gas/ Propane

Emissions (Corrected for 3% O2):

O2-6%,

CO-0ppm, Nox-19ppm

Certifications, CSA/ Ansi:

Pending

Highlights

Burner Nozzle Size:

3″

BTU/hr Output:

2.5MM

Combustion Chamber OD:

12.750″

Specifications

Total Length:

49.5″

Approximate Weight:

340 LB

Fuel Nozzle Pressure:

< 4 PSI

Performance

Forced Air Pressure:

< 15 PSI

Flame length:

< 8″

Liquid Cooled Flow Rate@ 60 PSI:

50 LPM

Approximate Output Temp.:

1010 C/1850 F

Approximate Fire Tube Exhaust:

175-200 C/350-400 F

Efficiency

Combustion Efficiency:

100%

Apparatus Efficiency (including electricity):

80-85% HHV

Fuel:

Natural Gas/ Propane

Emissions (Corrected for 3% O2):

O2-6%,

CO-0ppm, Nox-22ppm

Certifications, CSA/ Ansi:

Pending

Highlights

Burner Nozzle Size:

4″

BTU/hr Output:

3.5MM

Combustion Chamber OD:

12.750″

Specifications

Total Length:

49.5″

Approximate Weight:

375 LB

Fuel Nozzle Pressure:

< 5 PSI

Performance

Forced Air Pressure:

< 15 PSI

Flame length:

< 8″

Liquid Cooled Flow Rate@ 60 PSI:

50 LPM

Approximate Output Temp.:

1010 C/1850 F

Approximate Fire Tube Exhaust:

175-200 C/350-400 F

Efficiency

Combustion Efficiency:

100%

Apparatus Efficiency (including electricity):

80-85% HHV

Fuel:

Natural Gas/ Propane

Emissions (Corrected for 3% O2):

O2-6%,

CO-0ppm, Nox-27ppm

Certifications, CSA/ Ansi:

Pending

Our burners are scalable, using the following equipment

Glycol Loop Line Heater

The Absolute Extreme Burner™ technology creates a perfect burn environment where extremely high temperatures, significantly lower fuel consumption, and dramatically lower emissions exist in a near flameless, hot air environment.

Seamless Retrofit

Our adjusted NOx for O2 at 3% emissions of 17 – 25 PPM at 2.5MMBtu are well below the current accepted emission standard of 35 – 45 ppm. Our CO is zero (0) ppm and our CO2 ranges between 8.0 and 8.8%. With absolutely no reservation we can state that this burner has met and exceeded our expectations at each benchmark along the development path.