Products

BURNERS

1MM BTU Burner

Specifications

  • Burner Nozzle Size : 1″
  • BTU/hr Output : 300K
  • Combustion Chamber OD : 5.563″
  • Total Length : 24″
  • Approximate Weight : 90 LB
  • Fuel Nozzle Pressure : < 2 PSI
  • Forced Air Pressure : < 15 PSI
  • Flame length : < 8″
  • Liquid Cooled Flow Rate@ 60 PSI : 25 LPM
  • Approximate Output Temp. : 1010 C/1850 F
  • Approximate Fire Tube Exhaust : 175-200 C/350-400 F
  • Combustion Efficiency : 100%
  • Apparatus Efficiency (including electricity) : 80-85% HHV
  • Fuel : Natural Gas/ Propane
  • Emissions (Corrected for 3% O2) : O2-6%, CO-0ppm, Nox-15ppm
  • Certifications, CSA/ Ansi : Pending

3MM BTU Burner

Specifications

  • Burner Nozzle Size : 3″
  • BTU/hr Output : 2.5MM
  • Combustion Chamber OD : 12.750″
  • Total Length : 49.5″
  • Approximate Weight : 340 LB
  • Fuel Nozzle Pressure : < 4 PSI
  • Forced Air Pressure : < 15 PSI
  • Flame length : < 8″
  • Liquid Cooled Flow Rate@ 60 PSI : 50 LPM
  • Approximate Output Temp. : 1010 C/1850 F
  • Approximate Fire Tube Exhaust : 175-200 C/350-400 F
  • Combustion Efficiency : 100%
  • Apparatus Efficiency (including electricity) : 80-85% HHV
  • Fuel : Natural Gas/ Propane
  • Emissions (Corrected for 3% O2) : O2-6%, CO-0ppm, Nox-22ppm
  • Certifications, CSA/ Ansi : Pending

2MM BTU Burner

Specifications

  • Burner Nozzle Size : 2″
  • BTU/hr Output : 1.5MM
  • Combustion Chamber OD : 8.625″
  • Total Length : 35″
  • Approximate Weight : 145 LB
  • Fuel Nozzle Pressure : < 3 PSI
  • Forced Air Pressure : < 15 PSI
  • Flame length : < 8″
  • Liquid Cooled Flow Rate@ 60 PSI : 25 LPM
  • Approximate Output Temp. : 1010 C/1850 F
  • Approximate Fire Tube Exhaust : 175-200 C/350-400 F
  • Combustion Efficiency : 100%
  • Apparatus Efficiency (including electricity) : 80-85% HHV
  • Fuel : Natural Gas/ Propane
  • Emissions (Corrected for 3% O2) : O2-6%, CO-0ppm, Nox-19ppm
  • Certifications, CSA/ Ansi : Pending

4MM BTU Burner

Specifications

  • Burner Nozzle Size : 4″
  • BTU/hr Output : 3.5MM
  • Combustion Chamber OD : 12.750
  • Total Length : 49.5″
  • Approximate Weight : 375 LB
  • Fuel Nozzle Pressure : < 5 PSI
  • Forced Air Pressure : < 15 PSI
  • Flame length : < 8″
  • Liquid Cooled Flow Rate@ 60 PSI : 50 LPM
  • Approximate Output Temp. : 1010 C/1850 F
  • Approximate Fire Tube Exhaust : 175-200 C/350-400 F
  • Combustion Efficiency : 100%
  • Apparatus Efficiency (including electricity) : 80-85% HHV
  • Fuel : Natural Gas/ Propane
  • Emissions (Corrected for 3% O2) : O2-6%, CO-0ppm, Nox-27ppm
  • Certifications, CSA/ Ansi : Pending

SCALABILITY 

Glycol Loop Line Heater

Seamless Retrofit

BOOK A DEMO

Your Name (required)

Your Email (required)

Preferred Demo Date (required)